For more information: Contact Mesa Equipment Compressor Sales Telephone (505) 345-0284 |
![]() |
|
Product Overview Air/Watercooled Technical Data High Ambient Temperature Watercooled Technical Data MKIV Elektronikon Information |
|
|
GA 90-160 Aircooled, HAT (High Ambient Temperature), Oil Injected Rotary Screw Air Compressors Base unit supplied with the following equipment |
| The Pack Unit Standard Equipment Includes: | ||||
| - | Two-stage high efficiency inlet filter | - | Oil level indicator | |
| - | Air inlet valve/unloader assembly | - | Stainless steel plate and frame coolers (watercooled units) | |
| - | Rotary screw compressor element flange mounted to gear box |
- | Aftercooler and high efficiency moisture separator with manual and automatic drains |
|
| - | High precision gears according to AGMA Q13/DIN Class 5 |
- | Coolers constructed of welded aluminum (aircooled units) | |
| - | WEG NEMA premium efficient TEFC D-flanged main drive motor |
- | CSA/UL control cubicle with wye-delta starter and control transformer |
|
| - | ASME approved air/oil spearator tank and pressure relief valve |
- | Main base frame with fully enclosed metal floor | |
| - | Hinged/swivel air/oil separator tank cover | - | Vibration isolated compressor/drive assembly | |
| - | High efficiency air/oil spearator element with expanded surface area |
- | Full acoustical sound attenuating enclosure | |
| - | TEFC cooling fan motor (aircooled units) | - | Elektronikon® MKIV control & monitoring system | |
| - | Hinged cooling fan assembly (aircooled units) |
Full Feature Unit Includes: All of the Pack unit standard equipment, plus: - Integrated refrigerated dryer, ID, with: ° Interconnected piping ° Interconnected wiring ° R404a refrigerant (zero ozone depletion) ° Three valve by-pass on air circuit |
||
| - | Differerential pressure oil system w/oil cooler | |||
| - | Oil stop valves | |||
| - | Minimum pressure valve | |||
| - | Check valves | |||
| - | Thermostatic oilcooler by-pass valve | |||
| - | Oil filter, spin-on type | |||
| - | Factory oil fill | |||
| Compressor Model Number | GA 90 HAT | GA 110 HAT | GA 160 HAT | |||||||
| 100 | 125 | 150 | 100 | 125 | 150 | 100 | 125 | 150 | ||
| Horsepower | hp | 125 | 150 | 200 | ||||||
| Maximum Allowable Air Inlet Temperature Maximum Allowable Cooling Air Temperature |
°F | 122 | 122 | 122 | ||||||
| Capacity FAD (at reference conditions) (1) | cfm | 571 | 504 | 435 | 681 | 587 | 523 | 903 | 814 | 742 |
| Nominal Effective Operating Pressure | psig | 100 | 125 | 150 | 100 | 125 | 150 | 100 | 125 | 150 |
| Minimum Operating Pressure | psig | 58 | ||||||||
| Maximum Operating Pressure | psig | 107 | 132 | 157 | 107 | 132 | 157 | 107 | 132 | 157 |
| Sound Pressure Level (aircooled)(2) | dB(A) | 76 | 76 | 78 | ||||||
| Approx Shipping Weight | lbs | 6,950 | 6,950 | 8,200 | ||||||
| For additional information contact Mesa Equipment Compressor Sales or call (505) 345-0284 |
| Performance data at reference conditions, unless otherwise stated, according to ISO1217, Ed. 3, Annex C. |
|
(1) Corresponds to "Actual Volume Flow Rate" (ISO1217, Ed. 3). Measured by means of an orfice plate inserted in a circular cross section of pipe (acc. ISO 5167). Guaranteed with a tolerance of +4% for units with a flow rate above 530 cfm. Guaranteed with a tolerance of +5% for units with a flow rate above 53 to 530 cfm. Supply voltage 460V; Data may differ 0.5% maximum at other supply voltages. |
|
(2) Level measured according to CAGI-PNEUORP PN8NTC2.2 test code (ISO 9614.2 sound intensity scanning method). A correction factor for uncertainties of 3dB has to be added, to conform to the test code. The emission sound pressure level refers to free field conditions at 1 m distance. Possible noise from discharge line, accessories and/or ancillary equipment is not included. |